Canceling Loop Detection on the Multi-Instance CE

If the route loop detection is performed, the CE discards the route from the PE with the DN bit being 1.

Context

Perform the following steps on the MCE.

Procedure

  1. Access the system view.

    system-view

  2. Access the OSPF multi-instance view.

    ospf process-id [ router-id router-id ] vpn-instance vpn-instance-name

  3. Cancel loop detection.

    vpn-instance-capability simple

Copyright © Huawei Technologies Co., Ltd.