The threshold-exceeding trap function helps you learn NQA test situations in real time.
The device sends traps to the NMS only when the trap function is enabled and the NMS is configured. For details, see SNMP.
nqa test-instance admin-name test-name
| Item | Command | Description |
|---|---|---|
| Trap sending upon probe failures | ||
| Configuring the number of probe failures for which a trap is sent | probe-failtimes times | By default, a trap is sent if a probe fails. |
| Configuring trap sending upon probe failures | send-trap probefailure | By default, no trap is sent if a probe fails. |
| Trap sending upon test failures | ||
| Configuring the number of test failures for which a trap is sent | test-failtimes times | By default, a trap is sent if a test fails. |
| Configuring trap sending upon test failures | send-trap testfailure | By default, no trap is sent if a test fails. |
| Trap sending when the RTD exceeds the specified threshold | ||
| Configuring an RTD threshold | threshold rtd value | By default, no RTD threshold is configured. |
| Configuring the function of sending a trap if the RTD exceeds the specified threshold | send-trap rtd | By default, no trap is sent if the RTD exceeds the specified threshold. |
| Trap sending upon test completion | ||
| Configuring trap sending upon test completion | send-trap testcomplete | By default, no trap is sent when a test is complete. |
| Trap sending upon test result changes | ||
| Configuring trap sending upon test result changes | send-trap testresult-change | By default, no trap is sent when the test result is changed. |