By default, the alarm function is enabled.
Application
Scenario
After cluster configuration consistency check is
complete, if some configurations are inconsistent, an alarm is generated
to remind the administrator of modifying the configurations.
- You can run the cluster configuration auto-check warning enable command to enable the alarm function for configuration consistency
auto-check. After the alarm function is enabled, the device running
the check task displays the alarm and log based on the check result.
Both the alarm and log contain the names of inconsistent configurations.
- You can run the undo cluster configuration auto-check warning
enable command to disable the alarm function for configuration
consistency auto-check. After the alarm function is disabled, no alarms
are generated after check tasks are executed, and only logs are recorded.
- You can run the cluster configuration check command to
manually check whether the cluster numbers have the same configuration.
During this consistency check process, an alarm is sent if they have
different configurations, without being controlled by the cluster
configuration auto-check warning enable command.
Follow-Up Configuration
In case of cluster
configuration inconsistency, run the cluster sync config command
to implement batch backup or manually change the configurations to
be consistent.