display firewall emergency bypass

Function

The display firewall emergency bypass command displays the status of the emergency forwarding function.

Format

display firewall emergency bypass

Parameters

None

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

None

Example

# Display the status of the emergency forwarding function.

<sysname> display firewall emergency  bypass
 2018-04-11 11:01:19.080 +09:00 DST                                                                                                  
=====================================================================                                                               
                      Emergency Bypass Information                                                                                  
=====================================================================                                                               
 Master switch:   ON                                                                                                               
 Total timeout:   300(s)                                                                                                            
 Remaining time:  0(s)                                                                                                              
 Time to warning: 0(s)                                                                                                              
---------------------------------------------------------------------                                                               
 Function                              Switch  Status  BypassCount                                                                  
 Blacklist                             OFF     INIT    0                                                                            
 User management                       ON     BYPASS   2                                                                            
 Security policy                       OFF     INIT    0                                                                            
 Bandwidth management                  OFF     INIT    0                                                                            
 IKE certificate time validation       OFF     INIT    --                                                                           
 Intelligent awareness engine(IAE)     OFF     INIT    0                                                                            
 License(1320min remain today)         OFF     INIT    --                                                                           
 Source tracing & Top IP address log   OFF     INIT    0                                                                            
 HRP mirror session                    ON      ENABLE  2                                                                            
=====================================================================    
Table 1 Description of the display firewall emergency bypass command output

Item

Description

Master switch

State of the emergency forwarding function

Total timeout

Lifetime of the emergency forwarding function

Remaining time

Remaining time of the emergency forwarding function

Time to warning

Time when the system generates an alarm to remind the user that the function will be soon disabled

Function

Name of each function item of the emergency forwarding function

NOTE:

Models except the USG6510E/6510E-POE and USG6530E support HRP mirror session.

Switch

Indication of whether the emergency forwarding function is enabled.

  • ON: The emergency forwarding function is enabled.
  • OFF: The emergency forwarding function is disabled.

Status

Working status of the emergency forwarding function for an object

  • BYPASS: The emergency forwarding function takes effect for the object.
  • INIT: The emergency forwarding function does not take effect for the object.
  • ENABLE: Quick session backup is enabled.

BypassCount

Number of times the emergency forwarding function is invoked. This counter indicates whether the emergency forwarding function takes effect.