The display health command displays information about the health check of the boards in the device. The information includes CPU usage and memory usage.
<sysname> display health
-------------------------------------------------------------------------------
Slot Card Sensor SensorName Status Current(V) Lower(V) Upper(V)
-------------------------------------------------------------------------------
0 - 0 12V Normal 0.0000 0.0000 0.0000
---------------------------------------------------------------
Slot Card Sensor Status Current(C) Lower(C) Upper(C)
---------------------------------------------------------------
0 - 0 Normal 48 0 110
- 1 Normal 49 0 110
--------------------------------------------------------------------------
PowerID Online Mode State Current(A) Voltage(V) RealPwr(W)
--------------------------------------------------------------------------
2 Present AC Supply 5 12 60
3 Present AC Supply 5 12 60
-------------------------------------------------------------------------------
FanID FanNum Online Register Speed Mode Airflow
-------------------------------------------------------------------------------
FAN0 [1] Present Registered 0 (6840 ) AUTO Left-to-Right
System Memory Usage Information:
System memory usage at 2000-02-08 08:05:21
-------------------------------------------------------------------------------
Slot Total Memory(MB) Used Memory(MB) Used Percentage Upper Limit
-------------------------------------------------------------------------------
0 3818 1865 48% 90%
-------------------------------------------------------------------------------
System CPU Usage Information:
System cpu usage at 2000-02-08 08:05:21
-------------------------------------------------------------------------------
Slot CPU Usage Upper Limit
-------------------------------------------------------------------------------
0 71% 80%
-------------------------------------------------------------------------------
Disk Usage Information:
System disk usage at 2000-02-08 08:05:21
-------------------------------------------------------------------------------
Slot Device Total Memory(MB) Used Memory(MB) Used Percentage
-------------------------------------------------------------------------------
0 hda1: 1561 1008 64%
-------------------------------------------------------------------------------
Item |
Description |
|---|---|
Slot |
Slot ID |
Card |
Slot ID of a subcard |
Sensor |
Number of a voltage sensor Only the USG6610E/6620E, USG6615E/6625E, USG6630E/6650E, USG6635E/6655E, USG6680E, and USG6712E/6716E support this parameter. |
SensorName |
Name of a voltage sensor Only the USG6610E/6620E, USG6615E/6625E, USG6630E/6650E, USG6635E/6655E, USG6680E, and USG6712E/6716E support this parameter. |
Status |
Voltage alarm severity
Only the USG6610E/6620E, USG6615E/6625E, USG6630E/6650E, USG6635E/6655E, USG6680E, and USG6712E/6716E support this parameter. |
Current(V) |
Voltage, in V Only the USG6610E/6620E, USG6615E/6625E, USG6630E/6650E, USG6635E/6655E, USG6680E, and USG6712E/6716E support this parameter. |
Lower(V) |
Lowest voltage, in V Only the USG6610E/6620E, USG6615E/6625E, USG6630E/6650E, USG6635E/6655E, USG6680E, and USG6712E/6716E support this parameter. |
Upper(V) |
Highest voltage, in V Only the USG6610E/6620E, USG6615E/6625E, USG6630E/6650E, USG6635E/6655E, USG6680E, and USG6712E/6716E support this parameter. |
Sensor |
Number of a temperature sensor |
Status |
Temperature alarm severity
|
Current(C) |
Temperature, in C |
Lower(C) |
Lowest temperature, in C |
Upper(C) |
Highest temperature, in C |
PowerID |
Power module ID |
Online |
Whether a power module is installed
|
Mode |
Working mode
|
State |
Status of the power module
|
Current(A) |
Current, in A |
Voltage(V) |
Voltage, in V |
RealPwr(W) |
Real power, in W |
FanID |
ID of a fan module |
FanNum |
Number of fans |
Online |
Whether a fan module is installed
|
Register |
Whether a fan module is registered
|
Speed |
Fan speed |
Mode |
Rate adjustment mode of the fan module
|
Airflow |
Airflow, such as Left-to-Right |
Total Memory(MB) |
Total size of the memory, in MB |
Used Memory(MB) |
Size of used memory, in MB |
Used Percentage |
Percentage of used memory |
Upper Limit |
Alarm threshold of memory usage |
CPU Usage |
CPU usage |
Upper Limit |
Alarm threshold of the CPU usage |
Device |
Storage device |
Total Memory(MB) |
Total size of the memory, in MB |
Used Memory(MB) |
Size of used memory, in MB |
Used Percentage |
Percentage of used memory |