The display voltage command displays the status of the voltage sensor in the specified slot.
| Parameter | Description | Value |
|---|---|---|
slot-id |
Specifies the slot ID of the voltage sensor that is in position. |
- |
all |
Specifies all slot IDs of the voltage sensor that is in position. |
- |
In routine maintenance, you can run this command to check the device voltage.
This command depends on the hardware. If this command cannot be executed or no command output is displayed on a device, the device does not support this command.
[sysname] display voltage slot 0
-------------------------------------------------------------------------------
Slot Card Sensor SensorName Status Current(V) Lower(V) Upper(V)
-------------------------------------------------------------------------------
0 - 0 1.1V_CORE Normal 1.1000 1.0400 1.1500
- 1 3.3V Normal 3.3000 3.1200 3.4500
- 2 2.5V Normal 2.5200 2.3700 2.6100
- 3 1.5V Normal 1.4900 1.4200 1.5700
- 4 1.1V Normal 1.0900 1.0400 1.1500
- 5 0.75V_DDR Normal 0.7400 0.7100 0.7800
- 6 12V Normal 11.8800 11.4000 12.6000
Item |
Description |
|---|---|
Slot |
Slot ID of the sensor. |
Card |
Subcard of the voltage sensor. |
Sensor |
ID of the voltage sensor. |
SensorName |
Name of the voltage sensor. |
Status |
Status of the voltage sensor. |
Current(V) |
Current voltage. |
Lower(V) |
Minimum value of the normal voltage. |
Upper(V) |
Maximum value of the normal voltage. |