The firewall traffic-trace-source micro-burst sample-span command sets the period during which microburst traffic is sampled for traffic source tracing for one time.
The undo firewall traffic-trace-source micro-burst sample-span command restores the period during which microburst traffic is sampled for traffic source tracing for one time to the default value (100 ms).
firewall traffic-trace-source micro-burst sample-span time
undo firewall traffic-trace-source micro-burst sample-span
| Parameter | Description | Value |
|---|---|---|
time |
Specifies the period during which microburst traffic is sampled for traffic source tracing for one time. |
The value is an integer in the range from 10 to 2000, in milliseconds. |
Only the USG6510E/6510E-POE, USG6530E, USG6515E/6550E/6560E/6580E, and USG6525E/6555E/6565E/6575E-B/6585E/6605E-B, USG6615E/6625E and USG6635E/6655Esupport this command.
If the collected traffic data is inaccurate, you can adjust the sampling time based on the duration of microburst traffic generation.