The poe power-off time-range command applies a power-off period to an interface.
The undo poe power-off time-range command cancels the power-off period applies to an interface.
Parameter |
Description |
Value |
|---|---|---|
time-range-name |
Specifies the name of a power-off period. |
The value is a string of 1 to 32 characters starting with a letter. To prevent confusion, the name cannot be all. |
By default, there is no power-off period set for any interface.
Application Scenario
Run the poe power-off time-range command to apply a power-off period set in the system view to an interface. If the current time is within the power-off period, no power is supplied to the PD connected to the interface.
Pre-Configuration Task
Run the time-range and period-range commands in the system view to set a power-off period.
Precautions
If you switch the power supply management mode during the power-off period, the system determines the power supply according to the new mode. For example, if the manual mode is switched to the automatic mode during the power-off period, the interface is automatically powered on.
<sysname> system-view [sysname] time-range PoE [sysname-time-range-poe] period-range 18:00:00 to 23:00:00 working-day [sysname-time-range-poe] quit [sysname] interface GigabitEthernet 0/0/1 [sysname-GigabitEthernet0/0/1] poe power-off time-range PoE