< Home

put survey interval

Function

The put survey interval command sets an interval at which the survey result is sent.

The undo put survey interval command restores the sending interval to the default value (180 minutes).

Format

put survey interval interval

undo put survey interval

Parameters

Parameter Description Value
interval

Specifies an interval at which the survey result is sent.

The value is an integer ranging from 10 to 1440, in minutes. The default value is 180 minutes.

Views

Portal authentication template view

Default Level

2: Configuration level

Usage Guidelines

Only the USG6510E/6510E-POE/6530E supports this command.

By default, the survey result is sent every 180 minutes.

Example

# Set the interval for sending the survey result to 60 minutes.

<sysname> system-view
[sysname] user-manage portal-template template1
[sysname-portal-template-template1] put survey interval 60
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.