< Home

service-quality statistics

Function

The service-quality statistics enable command enables the service quality statistical analysis function.

The service-quality statistics cycle command specifies the service quality sampling cycle.

The service-quality statistics sampling-frequency command specifies the service quality statistical cycle.

undo service-quality statistics command disables the service quality statistical analysis function or cancels the service quality sampling cycle and statistical cycle configuration.

Format

service-quality statistics enable [ acl { basic-acl-number | advanced-acl-number } ]

service-quality statistics cycle cycle

service-quality statistics sampling-frequency sampling-frequency

undo service-quality statistics { enable | cycle | sampling-frequency }

Parameters

Parameter Description Value
acl { basic-acl-number | advanced-acl-number } Specifies the basic ACL or the advanced ACL. The value of basic-acl-number is an integer ranging from 2000 to 2999. The value of advanced-acl-number is an integer ranging from 3000 to 3999.
cycle cycle Specifies the service quality sampling cycle. The value is an integer ranging from 1 to 1440, in minutes. The default value is 30 minutes, meaning that the sampling cycle lasts 30 minutes after the service-quality statistics enable command is executed.
sampling-frequency sampling-frequency Specifies the service quality statistical analysis cycle.

The value is an integer ranging from 1 to 48. The default value is 1.

If the value is set to 2, a service quality statistical analysis cycle is twice the service quality sampling cycles, that is, the service quality statistical analysis cycle is 60 minutes.

In this case, you can run the display service-quality statistics result command to view the statistics 60 minutes after the service-quality statistics enable command is executed.

Views

System view

Default Level

2: Configuration

Usage Guidelines

By default, the service quality statistics function is disabled.

After the cycle or sampling-frequency parameter is modified, the service quality statistical analysis function must be restarted to apply the configuration changes.

Example

# Enable the function of service quality statistics.

<sysname> system-view
[sysname] service-quality statistics enable
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic