< Home

session sudden-change alarm enable

Function

The session sudden-change alarm enable command enables the alarm function for the sudden change of the session.

The undo session sudden-change alarm enable command disables the function.

Format

session sudden-change alarm enable

undo session sudden-change alarm enable

Parameters

None

Views

System view

Default Level

3: Management level

Usage Guidelines

By default, the function is enabled.

After the function is enabled, if the change rate of the session reaches the threshold in a specific period, alarm FWD_1.3.6.1.4.1.2011.6.122.15.3.4.7 hwSecStatSuddenChangeTrapOverThreshold is sent. The change rate threshold can be set using the session sudden-change alarm-threshold command.

Example

# Enable the alarm function for the sudden change of the session usage.

<sysname> system-view
[sysname] session sudden-change alarm enable
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >