isis timer retransmit

Function

The isis timer retransmit command configures the LSP retransmission interval over the P2P link.

Format

isis timer retransmit retransmit-interval

Parameters

Parameter Description Value
retransmit-interval

Specifies the retransmission interval of LSPs.

The value is integer ranging from 1 to 300 seconds.

Views

Interface view

Default Level

2: Configuration level

Usage Guidelines

This command is available to aid upgrade compatibility. It can only be run during the configuration restoration phase of the upgrade.

After the upgrade, this command is no longer supported, and it is replaced by the isis timer lsp-retransmit command.