(Optional) Configuring the Alarm Function for IP Address Exhaustion

Context

To receive notifications about IP address exhaustion, configure the DHCP to generate alarms for IP address exhaustion.

Procedure

  • Configure the alarm function in an interface address pool.
    1. Enter the system view.

      system-view

    2. Enter the interface view.

      interface interface-type interface-number

    3. Specify the percentage of alarms indicating the exhaustion of IP addresses and the percentage of clear alarms.

      dhcp server alarm ip-used percentage alarm-resume-percentage alarm-percentage

      By default, the percentage of the alarms is 100%, and the percentage of the clear alarms is 50%.

      When the address usage in the address pool reaches the alarm threshold, the device reports the alarm AM_1.3.6.1.4.1.2011.6.8.2.2.0.6 hwUsedIPReachThreshold. This alarm is reported only once within 10 minutes.

  • Configure the alarm function in a global address pool.
    1. Enter the system view.

      system-view

    2. Enter the global address pool view.

      ip pool ip-pool-name

    3. Specify the percentage of alarms indicating the exhaustion of IP addresses and the percentage of clear alarms.

      alarm ip-used percentage alarm-resume-percentage alarm-percentage

      By default, the percentage of the alarms is 100%, and the percentage of the clear alarms is 50%.

      When the address usage in the address pool reaches the alarm threshold, the device reports the alarm AM_1.3.6.1.4.1.2011.6.8.2.2.0.6 hwUsedIPReachThreshold. This alarm is reported only once within 10 minutes.