Function

The detect max-time command sets the maximum duration in which the SA module detects sessions.

The undo detect max-time command restores the maximum duration to the default value.

Format

detect max-time max-time

undo detect max-time

Parameters

Parameter Description Value

max-time

Specifies the maximum session detection duration.

The value is an integer ranging from 0 to 60, in minutes. The default value is 1.

Views

SA view

Default Level

2: Configuration level

Usage Guidelines

None

Example

# Set the maximum duration in which the SA module detects sessions to 5 minutes.

<sysname> system-view
[sysname] sa
[sysname-sa] detect max-time 5