< Home

flow-probe metadata-collect transfer-method

Function

The flow-probe metadata-collect transfer-method command configures the transfer mode of the metadata collected through the flow probe.

The undo flow-probe metadata-collect transfer-method command restores the default transfer mode of the metadata collected through the flow probe.

Format

flow-probe metadata-collect transfer-method { udp | ssl }

undo flow-probe metadata-collect transfer-method

Parameters

Parameter Description Value
udp

Uses UDP to transfer the collected metadata.

-

ssl

Uses SSL to transfer the collected metadata.

-

Views

System view

Default Level

2: Configuration level

Usage Guidelines

By default, UDP is used to transfer the metadata collected through the flow probe.

Example

# Set the transfer mode of the metadata collected through the flow probe to SSL.

<sysname> system-view
[sysname] flow-probe metadata-collect transfer-method ssl