Maintaining Alarms

After the alarm-related configuration is complete, you can check the configuration result and view or clear alarm-related information.

Checking Configuration Results

Run the commands listed in Table 1 in any view to check the alarm configuration result.

Table 1 Checking the alarm configuration

Operation

Command

Check the channel configuration.

display channel [ channel-number | channel-name ]

Check information recorded by the information center.

display info-center statistics

Check information in the trap buffer.

display trapbuffer [ size size-value ]

Clearing Alarm-related Information

Run the commands listed in Table 2 in user view to clear alarm-related information.

Alarm information cannot be restored after it is cleared. Perform the operation with caution.

Table 2 Clearing alarm-related information

Operation

Command

Clear statistics on every module in the information center.

reset info-center statistics

Clear information in the trap buffer.

reset trapbuffer