< Home

Configuring the Lower Limit of Up Member Interface for an Eth-Trunk Interface

When the number of Up member links falls below the lower limit, the Eth-Trunk interface goes Down. Setting the lower limit ensures the minimum bandwidth of the Eth-Trunk interface.

Procedure

  1. Access the system view.

    system-view

  2. Access the Eth-Trunk interface view.

    interface eth-trunk trunk-id

  3. Set the lower limit of Up member interfaces for the Eth-Trunk interface.

    least active-linknumber link-number

    The default value is 1. The Eth-Trunk interface is Up as long as one member interface is Up.

    • The lower limit can be set in either Layer-2 or Layer-3 mode.

    • To ensure normal forwarding, set the same lower limit for the Eth-Trunk interfaces on both ends of a trunk link.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >