< Home

cluster timer holding-multiplier

Function

The cluster timer holding-multiplier command sets Hello packet detection multiplier for the cluster.

The undo cluster timer holding-multiplier command restores the Hello packet detection multiplier to the default value.

Format

cluster timer holding-multiplier time

undo cluster timer holding-multiplier

Parameters

Parameter Description Value

time

Specifies a Hello packet detection multiplier for the cluster.

The value is an integer ranging from 3 to 60. The default value is 3.

Views

System view

Default Level

2: Configuration level

Usage Guidelines

After a cluster is created, master and backup devices in the cluster periodically send Hello packets to each other (backup devices will not send Hello packets to each other). If the master device does not receive Hello packets from a peer within the timeout period, it considers the peer not in the cluster any more.

Hello packet timeout period = Hello packet detection multiplier x Hello packet sending interval

Example

# Set the Hello packet detection multiplier to 5.

<sysname> system-view
[sysname] cluster timer holding-multiplier 5
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >