< Home

display alarm

Function

The display alarm slotslot-idslot-id command displays alarm information about the specified board.

The display alarm all command displays all the alarm information.

Format

display alarm { slot slot-id | all }

Parameters

Parameter Description Value

slot slot-id

Specifies the ID of the slot where an alarm is generated.

-

all

Indicates the alarm information on all the slots.

-

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

This command is used in routine maintenance of the device. When the device is running, you can use this command to view the alarm information to check whether the device is in normal operation. When a fault occurs, you can also use the command to fast locate the fault.

The display alarm all command contains alarms related to device management. When you run this command to query alarm information, the system turns on the SYS red indicator. To collect device alarm information, run the display alarm activel command.

Example

# Display all the current alarm information.

<sysname> display alarm all
----------------------------------------------------------------------------    
Index  Level      Date      Time                        Info                    
                                                                                
1      Major      18-07-09  20:11:20    SPU 7/0 : LINK of ILK is abnormal[OID:  
                                        1.3.6.1.4.1.2011.5.25.219.2.2.5,EntCod  
                                        e:140289]                               
2      Major      18-07-09  20:11:19    SPU 7/1 : LINK of ILK is abnormal[OID:  
                                        1.3.6.1.4.1.2011.5.25.219.2.2.5,EntCod  
                                        e:140289]                               
3      Major      18-07-04  12:57:05    Because of fatal error or exception oc  
                                        cur, the entity of Slot8 is resetting,  
                                         not ready[OID:1.3.6.1.4.1.2011.5.25.2  
                                        19.2.2.5,EntCode:132628]                
4      Warning    18-07-03  17:40:59    The air filter : Maybe it is not clean  
                                        ed as scheduled. Please clean it and r  
                                        un the reset dustproof run-time comman  
                                        d[OID:1.3.6.1.4.1.2011.5.25.129.2.1.9,  
                                        BasCode:67995]                          
5      Major      18-07-03  17:37:55    SlotID16 : PowerB2 present but no inpu  
                                        t[OID:1.3.6.1.4.1.2011.5.25.129.2.1.9,  
                                        BasCode:67638]                          
6      Major      18-07-03  17:37:55    SlotID16 : PowerB1 present but no inpu  
                                        t[OID:1.3.6.1.4.1.2011.5.25.129.2.1.9,  
                                        BasCode:67638]                          
----------------------------------------------------------------------------   

# Display the alarm information in slot 5.

<sysname> display alarm slot 5
----------------------------------------------------------------------------    
Index  Level      Date      Time                        Info                    
                                                                                
1      Major  15-03-05  11:25:40    The 48 V power supply for the board wa  
                                        s abnormal.[LPU 5]                      
----------------------------------------------------------------------------    
Table 1 Description of the display alarm all command output

Item

Description

Level

Level of the alarm information.

Date

Date of the alarm information.

Time

Time of the alarm information.

Info

Details about the alarm information.