memory-usage-dataplane sudden-change alarm-threshold

Function

The memory-usage-dataplane sudden-change alarm-threshold command sets the alarm threshold on sudden memory usage change on the data plane.

The undo memory-usage-dataplane sudden-change alarm-threshold command restores the alarm threshold on sudden memory usage change on the data plane to the default value.

Format

memory-usage-dataplane sudden-change alarm-threshold threshold-value

undo memory-usage-dataplane sudden-change alarm-threshold

Parameters

Parameter Description Value

threshold-value

Specifies the alarm threshold on sudden memory usage change on the data plane.

The value is an integer ranging from 1 to 99, in percentage (%). The default value is 40, and the recommended value is 30.

NOTE:

The threshold-value value cannot be too small. Otherwise, the device may output a large number of alarms.

Views

System view

Default Level

3: Management level

Usage Guidelines

If the change of the memory usage on the data plane within a specified period of time (60 seconds ) reaches the alarm threshold specified by threshold-value, the memory usage experiences a sudden change. For example, the alarm threshold on sudden memory usage change on the data plane is 40%, the existing memory usage on the is 85%, and the memory usage in the last second is 40%. In this case, the memory usage increases by 45%, exceeding the alarm threshold 40%. The device identifies this process as a sudden change on the memory usage.

If the change of the memory usage on the data plane within a specified period of time reaches the alarm threshold on sudden memory usage change, alarm ENTEXT_1.3.6.1.4.1.2011.5.25.31.2.0.30 hwEntityExtMemoryUsageSuddenChangeNotification is outputted. To make the sudden memory usage change alarm function take effect, you must run the memory-usage-dataplane sudden-change alarm enable command to enable it.

If the alarm threshold on sudden memory usage change on the data plane is set to 40%, the existing memory usage of the is 100%, and the memory usage in the last second is 70%, the memory usage increases by 30%. In this case, the alarm on sudden memory usage change is not outputted. Instead, alarm ENTEXT_1.3.6.1.4.1.2011.5.25.31.2.0.5 hwEntityExtMemUsageThresholdNotification is outputted.

Example

# Set the alarm threshold on sudden memory usage change to 30%.

<sysname> system-view
[sysname] memory-usage-dataplane sudden-change alarm-threshold 30
Info: Successed in setting the alarm of the sudden change in memory-usage-dataplane.