< Home

memory-usage-dataplane sudden-change alarm enable

Function

The memory-usage-dataplane sudden-change alarm enable command enables the sudden memory usage change alarm function for the data plane.

The undo memory-usage-dataplane sudden-change alarm enable command disables the sudden memory usage change alarm function for the data plane.

Format

memory-usage-dataplane sudden-change alarm enable

undo memory-usage-dataplane sudden-change alarm enable

Parameters

None.

Views

System view

Default Level

3: Management level

Usage Guidelines

By default, the sudden memory usage change alarm function is enabled.

In a scenario where this function is enabled, if the change of the memory usage on the data plane within a specified period of time reaches the alarm threshold on sudden memory usage change, alarm ENTEXT_1.3.6.1.4.1.2011.5.25.31.2.0.30 hwEntityExtMemoryUsageSuddenChangeNotification is outputted. You can run the memory-usage-dataplane sudden-change alarm-threshold command to set the alarm threshold on sudden memory usage change.

Example

# Enable the sudden memory usage change alarm function on the data plane.

<sysname> system-view
[sysname] memory-usage-dataplane sudden-change alarm enable
Info: Enable the alarm of the sudden change in memory-usage-dataplane successful.