< Home

set transceiver-monitoring

Function

The set transceiver-monitoring command enables or disables the function of monitoring the optical transceiver power.

By default, Versions earlier than V600R007C20SPC300, the function of monitoring the optical transceiver power is enabled, V600R007C20SPC300 and later versions, the function of monitoring the optical transceiver power is disabled.

Format

set transceiver-monitoring { enable | disable }

Parameters

Parameter Description Value

enable

Enables the function of monitoring the optical transceiver power.

-

disable

Disables the function of monitoring the optical transceiver power.

-

Views

System view

Default Level

3: Management level

Usage Guidelines

After the function of monitoring the optical transceiver power is enabled, the device checks the optical transceiver power based on the interval specified by the set transceiver-monitoring interval interval-time command.

If the optical power is abnormal or recovers from the abnormal state, the following logs are generated:

If the optical power is abnormal due to certain links or transceivers, you can run the set transceiver-monitoring disable command to disable the function of monitoring the optical transceiver power to prevent the preceding logs from being continuously generated.

Example

# Enable the function of monitoring the optical transceiver power.

<sysname> system-view
[sysname] set transceiver-monitoring enable
Copyright © Huawei Technologies Co., Ltd.