< Home

set transceiver-monitoring interval

Function

The set transceiver-monitoring interval command sets the interval for monitoring the optical transceiver power.

The undo set transceiver-monitoring interval command restores the interval for monitoring the optical transceiver power to the default value.

Format

set transceiver-monitoring interval interval-time

undo set transceiver-monitoring interval

Parameters

Parameter Description Value
interval-time

Specifies the interval for monitoring the optical transceiver power.

The value is an integer ranging from 5 to 300, in seconds. The default value is 10 seconds.

Views

System view

Default Level

3: Management level

Usage Guidelines

None

Example

# Set the interval for monitoring the optical transceiver power to 20 seconds.

<sysname> system-view
[sysname] set transceiver-monitoring interval 20
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >