< Home

smart-link flush send

Function

The smart-link flush send vlan command enables an active interface to send flush packets in 1:1 active/standby mode when the switchover between the primary and backup interfaces is performed.

The undo smart-link flush send command disables an active interface to send flush packets in 1:1 active/standby mode when the switchover between the primary and backup interfaces is performed.

By default, an active interface is disabled from sending flush packets in 1:1 active/standby mode when the switchover between the primary and backup interfaces is performed.

Format

smart-link flush send vlan vlan-id

undo smart-link flush send

Parameters

Parameter Description Value
vlan vlan-id Specifies the VLAN ID of SmartLink flush packets. The value is an integer ranging from 1 to 4094.

Views

Layer-2 Eth-Trunk interface view

Default Level

2: Configuration level

Usage Guidelines

The Eth-Trunk should work in 1:1 active/standby mode before the command is configured. If you need change the operation mode of an Eth-Trunk, run the mode command to change it.

After the command is configured, when the switchover between the primary and backup interfaces is performed, the active interface sends flush packets to inform the peer of the aging of MAC addresses. In this manner, the data transmission interruption that is caused by asynchronous MAC addresses can be avoided.

Example

# Enable Eth-Trunk 1 to send flush packets of VLAN 1000.

<sysname> system-view
[sysname] interface eth-trunk 1
[sysname-Eth-Trunk1] portswitch
[sysname-Eth-Trunk1] mode manual backup
[sysname-Eth-Trunk1] smart-link flush send vlan 1000