The info-center trapbuffer command enables the alarm buffer, sets the channel for outputting the alarm information and sets the size of the alarm buffer.
The undo info-center trapbuffer command cancels the current configuration.
info-center trapbuffer [ channel { channel-number | channel-name } | size buffersize ] *
undo info-center trapbuffer [ channel | size ]
undo info-center trapbuffer { channel { channel-number | channel-name } | size buffersize } *
| Parameter | Description | Value |
|---|---|---|
| channel | Sets the channel for outputting information to the alarm buffer. | - |
| channel-number | Specifies the channel number. | It ranges from 0 to 9. That is, the system has 10 channels. |
| channel-name | Specifies a channel name. | The name is a string of 1 to 30 case-insensitive characters without spaces, hyphens (-), slashes (\), and anti-slashes (/). |
| size | Sets the size of the alarm buffer. | - |
| buffersize | Sets the size of the alarm buffer (the amount of information in the buffer). | It is an integer ranging from 0 to 1024. |