The lacp collector delay command configures the value of the CollectorMaxDelay field in an LACPDU.
The undo lacp collector delay command restores the default value of the CollectorMaxDelay field in an LACPDU.
The default value of the CollectorMaxDelay field is 0 in an LACPDU.
| Parameter | Description | Value |
|---|---|---|
| delay-time | Specifies the value of the CollectorMaxDelay field in an LACPDU. | The value is an integer ranging from 0 to 65535, in 10 microseconds. |
Prerequisites
The mode lacp-static command has been run in the Eth-Trunk interface view to configure the Eth-Trunk interface to work in static LACP mode.
Precautions
For a Huawei device, the value of the CollectorMaxDelay field is valid from 0 to 65535. Even though the member interfaces of the same Eth-Trunk interface receive LACPDUs with different CollectorMaxDelay values, the device can process them without deteriorating its CPU performance.